CDNLD - FRESH KOTE INTERIOR SEMI-GLOSS, 403183

  • MSDS: CDNLD
  • Manufacturer: M A BRUDER AND SONS INC
  • Product Name: FRESH KOTE INTERIOR SEMI-GLOSS, 403183
  • National Stock Number: 8010-00N077554
Product Identification

Product ID:FRESH KOTE INTERIOR SEMI-GLOSS, 403183
MSDS Date:11/06/1992
FSC:8010
NIIN:00N077554
MSDS Number: CDNLD

Responsible Party
M A BRUDER & SONS INC
600 REED RD
BROOMALL, PA 19008
US

Emergency Phone: 215-353-5100

Info Phone: 215-359-3635

Cage: 85519

Contractor
M A BRUDER & SONS INC
600 BROOMALL, PA 19008 US

Telephone: 610-353-5100;610-359-3635

Cage: 85519

Ingredients

TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 11-30%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


CALCIUM CARBONATE

CAS: 1317-65-3

RTECS: EV9580000

Fraction By Weight: 11-30%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


10 @ 25C.

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: 1-10%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


2 @ 25C.

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 11-30%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM


KEROSENE (PETROLEUM), HYDROTREATED; (PETROLEUM DISTILLATE).

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: 1-10%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


ALKYD RESIN

CAS: 66070-93-7

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


ALKYD RESIN

CAS: 67762-15-6

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:IRRIT OF RESP TRACT. PRLNG INHAL
MAY LEAD TO FATG, DROW, DIZZ &/OR LT HEAD, HDCH, LACK OF COORD,
NAUS, VOMIT, CNS DEPRESS, ANESTH EFT/NARCOS. SKIN CONT:IRRIT.
PRLNG/RPTD CONT CAN CAUSE DERM, DEF AT. EYE CONT:IRRIT. PRLNG/RPTD
CONT CANCAUSE BLURRED VISION, REDNESS, TEARING, SEV IRRIT.
INGEST:AMTS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INGESTED INCIDENTAL TO CONSUMER &
INDUS HNDLG ARE NOT LIKELY TO CAUSE INJURY; HOWEVER, INGEST OF LGR
AMTS MAY CAUSE LUNG INFLAMM & DMG DUE TO ASPIR OF MATL INTO LUNGS.
NOTICE:RPTS HAVE ASSOC RPTD & PRLNG OCCUP OVEREXP TO SOLVS W/PERM
BRAIN & NERV SYS DMG. INTENTIONAL MISUSE BY DELIB CONC & INHALING
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. RESTORE & SUPPORT CONTINUED
BREATHING. HAVE TRAINED PERSON GIVE OXYGEN IF NECESSARY. GET
EMERGENCY MED ATTN. SKIN:WASH OFF QUICKLY W/PLENTY OF WATER, THEN
SOAP & WATER; REMO VE & WASH CONTAMINATED CLOTHING BEFORE REUSE.
EYES:FLUSH IMMED W/LARGE AMOUNTS OF WATER, ESP UNDER LIDS, FOR AT
LEAST 15 MINUTES. OBTAIN EMERGENCY MED TREATMENT. INGEST:OBTAIN
MEDICAL TREATMENT IMMED.

Fire Fighting

Flash Point Method:SCC
Flash Point:100F,38C
Lower Limits:SEE INGS
Extinguishing Media:DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER MAY BE USED TO COOL & PROTECT EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:COMBUST LIQ - CLASS II. CLSD CNTNRS MAY
EXPLODE WHEN EXPOS TO EXTREME HEAT/FIRE. VAPS CAN FORM EXPLO MIXTS
IN AIR AT ELEVATED TEMPS. MAY DECOMP UNDER (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAME, HOT
SURFACES & ELECTRICAL, STATIC SPARKS). VENTILATE AREA & AVOID
BREATHING VAPORS. CONTAIN & REMOVE W/INERT ABSORBENT MATERIAL USING
NON-SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE IN SUN/>100F. STORE LG
QTYS IN BLDGS DESIGNED FOR STOR OF FLAMM/COMBUST LIQS. DO NOT TAKE
INTERNALLY. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:DO NOT WELD/FLAME CUT W/OUT PROPER VENT TO INSURE
AREA IS FREE OF FLAMM VAPS. DO NOT CUT, PUNCTURE/WELD ON/NEAR
CNTNR. RAGS/WASTE CNTNG OIL BASED PAINT/VARNISH THAT PRESENT LG
AIR-TO-OIL INTERFACE WIL L OXIDIZE & MAY IGNITE SPONT & (SUPDAT)

Exposure Controls

Respiratory Protection:CONTROL ENVIRON CONCS BELOW APPLIC STDS. NIOSH
APPRVD CHEM MECH FILTER RESP DESIGNED TO REMOVE COMBINATION OF
PARTICULATE & VAPS(TC23C/EQUIV). ENTRANCE INTO CLSD STOR TANKS-USE
APPROP NIOSH APPRVD RES P/AIRLINE FOR POSS EXPOS TO SOLV(SUPDAT)
Ventilation:ALL APPLICATION AREAS SHOULD BE VENTILATED I/A/W OSHA
REGULATION 29 CFR 1910 DURING USE & UNTIL AREA IS FREE OF VAPORS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:FIRE CONDITIONS EMITTING IRRITANT &/OR TOXIC GASES. EFTS OF
OVEREXP:CONTENTS MAY BE HARMFUL OR FATAL. OTHER PREC:SHOULD BE
PLACED IN METAL CONTAINER. RESP PROT:OR CHEMICAL FUMES.

Chemical Properties

Boiling Pt:B.P. Text:>310F,>154C
Vapor Pres:SEE INGS
Spec Gravity:1.13-1.29
Evaporation Rate & Reference:SLOWER THAN ETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:45-52

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS, ACIDS, BASES, AMINES.
Stability Condition to Avoid:ELEVATED TEMPERATURES. CONTACT W/OXIDIZING
AGENTS.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE I/A/W LOCAL, STATE & FEDERAL
REGULATIONS. AVOID DISCHARGE TO NATURAL WATERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.